Size |
N/A 1-1/4" |
End Connection |
N/A Socket/Threaded |
Operating Pressure [Max] |
N/A 250 psi |
Cv Coefficient |
N/A 75.0 |
Valve Material |
N/A PVC |
Seat Material |
N/A PTFE |
O-Ring Material |
N/A EPDM |
Method of Operation |
N/A Actuated |
Actuator Type |
N/A Electric |
Operation |
N/A On / Off |
Enclosure |
N/A NEMA4/4X |
Enclosure Material |
N/A Aluminum Dry Powder Coated |
Standard Voltage |
N/A 120VAC |
N/A
All 1/4" - 2" thermoplastic ball valves shall be manufactured with PVC Type 1, Grade 1 (ASTM D1784, Cell Classification 12454) or CPVC (ASTM
D1784, Cell Classification 23447). All sizes of shall be of true union design. Valve body shall contain an integral top mounting flange with dimensions
and bolt circles conforming to ISO 5211. Valve to include as standard sliding lock-out plate that interlocks with integral flange on body for lock-out /
tag-out. The valve has four locations for attaching a padlock. Body shall incorporate molded in foot pad for panel or rail mounting.
All O-rings shall be EPDM or FPM. Seats shall be PTFE as standard. Seats for 1/4" - 2" valves shall be reversible to allow field rebuild. Valves 2" and
smaller shall have a floating ball and System2™ seat carrier design that moves with the seat to affect a double seal to flow through a closed valve, and
require no adjustment. The handle shall be retained without any metal fasteners and made from GFPP with UV Inhibitor. Balls must be full-port design
and fully sphere shape. Stem shall contain double o-rings, and shall be blowout-proof design. Valve stem design shall be such that any torsional failure
occurs outside of the two stem o-rings. |
N/A
All Electric actuators shall feature a high efficiency reversing DC Brush-type Class B motor for 12vac/vdc and 24vac/vdc applications, and a split-phase capacitor thermally protected Class F reversing motor for 120V and 230V applications. Actuators shall be supplied with two primary travel-limiting switches and two standard auxiliary independently adjustable volt-free form A switches rated at 250vac 3A for remote indication of end of travel limits. Actuator positioning shall be via field generated on/off control switching supply voltage feeding the actuator. |
N/A Typical applications or installations include but are not limited to municipal waste and water treatment, clean water technology, chemical transfer and processing, aquatic and animal life support systems, mining and mineral processing, metal plating / surface finishing, marine, pulp and paper, landfills / environmental infrastructure and other demanding applications. |
N/A
System2™ Sealing Technology provides longer cycle life |