BYV14040A0EG000
Valve Size
N/A 4 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 600
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV22040A0EG000
Valve Size
N/A 4 in
Body Material
N/A CPVC
Disc Material
N/A CPVC
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 600
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV44040A0EG000
Valve Size
N/A 4 in
Body Material
N/A GFPP
Disc Material
N/A GFPP
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 600
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV11060A0EG000
Valve Size
N/A 6 in
Body Material
N/A PVC
Disc Material
N/A PVC
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 1300
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV14060A0EG000
Valve Size
N/A 6 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 1300
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV22060A0EG000
Valve Size
N/A 6 in
Body Material
N/A CPVC
Disc Material
N/A CPVC
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 1300
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV44060A0EG000
Valve Size
N/A 6 in
Body Material
N/A GFPP
Disc Material
N/A GFPP
Liner Material
N/A EPDM
Flow Coefficient Cv
N/A 1300
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV11080A0NG000
Valve Size
N/A 8 in
Body Material
N/A PVC
Disc Material
N/A PVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 2500
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV11100A0NG000
Valve Size
N/A 10 in
Body Material
N/A PVC
Disc Material
N/A PVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 4700
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV11120A0NG000
Valve Size
N/A 12 in
Body Material
N/A PVC
Disc Material
N/A PVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 7100
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV14080A0NG000
Valve Size
N/A 8 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 2500
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV14100A0NG000
Valve Size
N/A 10 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 4700
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV14120A0NG000
Valve Size
N/A 12 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 7100
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV22080A0NG000
Valve Size
N/A 8 in
Body Material
N/A CPVC
Disc Material
N/A CPVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 2500
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV22100A0NG000
Valve Size
N/A 10 in
Body Material
N/A CPVC
Disc Material
N/A CPVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 4700
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV22120A0NG000
Valve Size
N/A 12 in
Body Material
N/A CPVC
Disc Material
N/A CPVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 7100
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV44080A0NG000
Valve Size
N/A 8 in
Body Material
N/A GFPP
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 2500
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV44100A0NG000
Valve Size
N/A 10 in
Body Material
N/A GFPP
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 4700
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV44120A0NG000
Valve Size
N/A 12 in
Body Material
N/A GFPP
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 7100
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV11020A0NG000
Valve Size
N/A 2 in
Body Material
N/A PVC
Disc Material
N/A PVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 125
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV14020A0NG000
Valve Size
N/A 2 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 125
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV22020A0NG000
Valve Size
N/A 2 in
Body Material
N/A CPVC
Disc Material
N/A CPVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 125
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV44020A0NG000
Valve Size
N/A 2 in
Body Material
N/A GFPP
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 125
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV11025A0NG000
Valve Size
N/A 2 1/2 in
Body Material
N/A PVC
Disc Material
N/A PVC
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 190
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A
BYV14025A0NG000
Valve Size
N/A 2 1/2 in
Body Material
N/A PVC
Disc Material
N/A GFPP
Liner Material
N/A Nitrile
Flow Coefficient Cv
N/A 190
Pressure Rating at 70°F
N/A 150 psi 10 bar
CAD
N/A
Revit
N/A